ASYNC-001
ASYNC-001 Framing Errors in Data Capture
Framing Errors in Data Capture
If your data (in the Event Display) contains numerous framing errors, one of two things is wrong.
- The I/O Configuration (baud rate, word lenght, parity) is set up incorrectly. Check that the configuration in FTS matches that of the circuit under test. If not correct it.
- If you're sure that your configuration is correct and you're using a high-speed card (one with a maximum baud rate of greater than 115.2K, such as the Quatech DSP-100), you may have encountered a bug. Try changing the baud rate in the I/O configuration to 1/8 of the actual baud rate (for example, if your circuit is running at 9600 baud, set the I/O config to 1200). If that doesn't give you clean data, try 1/2 or 1/4. One of these settings should fix the problem.
|