See the Details - ZigBee Decoding
User selectable protocol level tabs in MeshDecoders Frame
Display enables you to get at the information that you want to
see fast. MeshDecoder decodes the ZigBee Cluster Library and
with one click you can see the important data, the set point is
35 degrees or the switch is off. Some ZigBee analyzers do not
decode the ZigBee Cluster Library. Frontline's MeshDecoder also
provides you with Line Quality Information (LQI).

Communications Decoding - ZigBee
Frame 345: (Host) Len=35
802.15.4 MAC:
Frame Control:
Frame Type: Data
Security: Disabled
Frame Pending: No
Acknowledgement Request: Yes
PAN ID Compression: Yes
Reserved: 0x000
Destination Addressing Mode: 16 bit short address
Version: IEEE Std 802.15.4-2003
Source Addressing Mode: 64 bit short address
Sequence Number: 253 Destination PAN
Identifier: 0x1aaa Destination Address: 0x00:00 Source
Address: 0x79:73
Radio Supplied Information:
Frame Check Sequence: 0x6e1f
LQI: 255
ZigBee Network:
NWK Header:
Frame Control:
Frame Type: Data
Protocol Version: 2
Discover route: Enable Route Discovery
Multicast Flag: Unicat or Broadcast
Security: Disabled
Source Route Subframe: Absent
Destination IEEE address: Absent
Source IEEE address: Absent
Reserved: 0x0
Routing Fields:
Destination Address: 0x00:00
Source Address: 0x79:73
Broadcast Radius: 10
Broadcast Sequence Number: 230
ZigBee APS:
APS Header:
Frame control:
Frame Type: Data
Delivery Mode: Normal unicast delivery
Indirect Address Mode: Not Relevant
Security: Disabled
Acknowledgement Requested: No
Reserved: 0
Destination Endpoint: Application 0x08
Cluster Identifier: Temperature measurement
Profile Identifier: Home Automation
Source Endpoint: Application 0x08
APS Counter: 176
ZigBee Cluster Library:
Cluster (from APS layer): Temperature
measurement
Control: 0x00
Frame Type sub-field: Entire profile Manfacturer
field present: No Command is from: Client Disable
default response: No
Sequence: 67 Command: Report attributes
Attribute Report:
Attribute: MeasuredValue Temperature:
34.0 C
|